Airflow: 150~500m³/h
Model: TFKC A2 series
1、Fresh air +Energy recovery ventilation
2、Airflow: 150-500 m³/h
3、Enthalpy exchange core
4、Filter: G4 primary filter+H12(can be customized)
5、Buckle type bottom maintenance easy replace filters
6、Customize as you want.
7、The up to 200pa static pressure design of the energy recovery ventilation(ERV) fully guarantees the arrival of air volume even when the ground air supply.
• BLDC motor, more save energy
The high-efficiency brushless DC motor is built into the Smart energy recovery ventilation, which can reduce the power consumption by 70% and save energy significantly. VSD control is suitable for most engineering air volume and ESP requirements.
• The energy recovery core (enthalpy exchanger)
Featuring high moisture permeability, good air tightness, good tear resistance and aging resistance, the core is specially designed for efficient energy recovery ventilation. The gaps between the fibers are so small that only water molecules with small diameters can pass through, not odor molecules with large diameters. In this way, temperature and humidity can be recovered smoothly through the energy recovery ventilation process, preventing pollutants from seeping into the fresh air.
• Energy saving principle
The energy recovery ventilation process follows the heat recovery calculating equation:SA temp.=(RA temp.−OA temp.)×temp. recovery efficiency + OA temp.
Example:14.8℃=(20℃−0℃)×74%+0℃
Heat recovery calculating equation
SA temp.=(RA temp.−OA temp.)×temp. recovery efficiency + OA temp.
Example:27.8℃=(33℃−26℃)×74%
| Air flow (m³/h) |
Energy recovery efficiency (%) | Electricity saving in summer (kW·h) |
Electricity saving in winter(kW·h) | Electricity saving in a year(kW·h) | Running costs saving(USD) |
| 250 | 60-76 | 1002.6 | 2341.3 | 3343.9 | 267.5 |
FRONT VIEW
SIDE VIEW
|
Model
|
A
|
B |
C |
D |
E |
F |
G |
H |
I |
d |
|
TFKC-015(A2series) |
660 |
690 |
710 |
635 |
465 |
830 |
190 |
200 |
420 |
114 |
|
TFKC-025(A2series) |
660 |
690 |
710 |
635 |
465 |
830 |
190 |
200 |
420 |
114 |
|
TFKC-030(A2series) |
735 |
735 |
680 |
785 |
500 |
875 |
245 |
250 |
445 |
144 |
|
TFKC-035(A2series) |
735 |
735 |
680 |
785 |
500 |
875 |
245 |
250 |
445 |
144 |
|
TFKC-050(A2series) |
860 |
735 |
910 |
675 |
600 |
895 |
240 |
270 |
540 |
194 |
|
Model |
Rated Airflow (m³/h) |
Rated E.S.P(Pa) |
Temp.Eff. (%) |
Noise (dB(A)) |
Purification efficiency |
Volt. (V/Hz) |
Power input (W) |
N.W(Kg) |
Size(mm) |
Control form |
Connect Size |
| TFKC-015(A2-1D2) | 150 | 100(200) | 75-80 | 32 | 99% | 210-240/50 | 75 | 28 | 690*660*220 | Intelligent control/APP | φ110 |
| TFKC-025(A2-1D2) | 250 | 100(160) | 73-81 | 36 | 210-240/50 | 90 | 28 | 690*660*220 | φ110 | ||
| TFKC-030(A2-1D2) | 300 | 100(200) | 74~82 | 38 | 210-240/50 | 120 | 35 | 735*735*265 | Φ150 | ||
| TFKC-035(A2-1D2) | 350 | 100(200) | 74-82 | 39 | 210-240/50 | 150 | 35 | 735*735*265 | φ150 | ||
| TFKC-050(A2-1D2) | 500 | 100(200) | 76-84 | 42 | 210-240/50 | 220 | 41 | 735*860*285 | φ200 |
TFKC series air volume-static pressure curve
Air flow: 250m³/h
Running time of air conditioning system with energy recovery ventilation:
Summer: 24h/day × 122 days = 2928 h (Jun. to Sep.)
Winter: 24h/day × 120 days = 2880 h (Nov. to Mar.)
Electric charge: 0.08 USD/kW·h
Indoor conditions: Cooling 26℃ (RH 50%), Heating 20℃ (RH 50%)
Outdoor conditions: Cooling 33.2℃ (RH 59%), Heating -10℃ (RH 45%)
• Double purification protection:
Primary filter + high efficiency filter can filter 0.3μm particles, and the filtration efficiency is as high as 99.9%, ensuring cleaner air throughout the energy recovery ventilation process.
G4*2 (Default is white) + H12 (Customizable)
A: Primary purification (G4):
The primary filter is suitable for the primary filtration of energy recovery ventilation systems, mainly used for filtering dust particles above 0.5μm; the primary filter can be reused after washing.
B: High efficiency purification (H12):
Effectively purify PM2.5 particulate. For 0.1 micron and 0.3 micron particles, the purification efficiency reaches 99.998%. It traps 99.9% of bacteria and viruses and causes them to die from dehydration within 72 hours, helping maintain clean air throughout the energy recovery ventilation process.
Tuya APP can be used for remote control of the energy recovery ventilation system.
App is available for iOS and Android phones with the following functions: